Business parks along the A1 and M62 corridor
Sherburn in Elmet is a growing town in the Selby area, handy for the A1 and the M62. Being on that corridor has brought business and industrial parks, which sit alongside the old village centre and a lot of new-build housing.
On the business parks, hardly anyone asks us to cool a whole warehouse. They want the rooms where people sit sorted out: offices, meeting rooms, canteens, welfare areas, the transport office tucked into the corner of a big unit.
Offices inside warehouse units
Mezzanine and ground-floor offices built inside a big shed usually sit under a metal roof, next to loading doors or a busy operational area. They get very warm in summer and cold in winter, and opening a window can let in dust, noise or fumes from the yard.
Metal roofs and solar gain
Lightweight roofs heat up fast in the sun and radiate warmth into the rooms below, especially a mezzanine office near the roof line. We allow for that extra heat when sizing.
Getting pipework to the outside
From an internal office to an outdoor unit on the external wall or roof can be a long way, and the route may cross racking, loading areas or fire-rated walls. We agree it with the site at the survey and write it into the quote.
Canteens and welfare areas
A staff room with kettles, microwaves and fridges, where a shift change brings everyone in at once, needs more capacity than the floor area suggests. On a long, warm shift, a comfortable break room makes a real difference.

Zoning offices, meeting rooms and staff spaces
Rooms on the same site have different loads and different hours, so one thermostat rarely suits them all. Zoning gives each area its own indoor unit and control. The office air conditioning page goes into more detail.
| Area | Main heat sources | Suggested approach |
|---|---|---|
| Open-plan office | People, computers, lighting, glazing | Ceiling cassettes for even air distribution |
| Meeting room | Short bursts of high occupancy | Separate unit with its own control |
| Transport or shift office | Screens running around the clock | Heavy-duty wall unit sized for continuous use |
| Canteen or welfare room | Appliances and shift changeovers | Wall unit or cassette with a higher capacity |
| Comms or server cupboard | IT equipment running constantly | Dedicated system independent of office comfort cooling |
Bigger sites may suit a system where several indoor units share outdoor equipment. Smaller ones often do better with separate split systems. We’ll explain the trade-offs, and there’s more on larger projects under commercial air conditioning.
Server rooms and comms cupboards
A small comms cupboard with a switch, a router and a couple of servers can overheat quickly with the door shut, and IT kit generally runs more reliably at a steady, moderate temperature. Office comfort cooling isn’t the answer, because it’s often off at night and at weekends.
- Use a dedicated unit that runs whenever the equipment does
- Size it for the equipment’s heat output, with some room for growth
- Make sure condensate drains reliably, using a pump if gravity isn’t possible
- Keep the unit serviced, as a clogged filter can let temperatures creep up unnoticed
Why a dedicated system matters
Office cooling is designed around people and working hours. A comms room needs steady cooling round the clock, all year, including cold winter nights when the office units are heating or switched off. Giving the IT space its own system avoids that clash, and a fault in one won’t take out the other.
Monitoring the room
A simple temperature alarm or logger gives early warning if the cooling unit stops, so you can deal with it before the equipment shuts itself down.
Worth checking
If your IT supplier gives a maximum room temperature, pass it on at the survey so we can size the system to stay below it.
Can new-build estates in Sherburn in Elmet take air conditioning?
Yes. New-builds are usually among the easiest homes to fit, with cavity walls, modern wiring and gardens you can get into. They often need it more, too. Well-insulated, airtight houses trap heat in summer, upstairs bedrooms worst of all, and estates in nearby Selby have exactly the same problem.
The rooms that need it most
- Bedrooms facing south or west, or with a warm roof above
- Loft conversions and dormer rooms
- Open-plan kitchen-diners with bifold doors or rooflights
- Home offices used all day with the door closed
Before you commit
Check your deeds and any builder warranty for conditions about external alterations, and whether the estate has rules about equipment on the front of the house. Putting the outdoor unit at the back or side usually avoids any trouble. Our domestic air conditioning and bedroom air conditioning pages cover home systems in more depth.
Electrics, condensate and refrigerant rules
Commercial landlords and facilities managers will want to know the job’s been done properly. These are the technical points they usually ask about, and the same standards apply to every air conditioning installation we do, home or business.
- Electrical supply
- Many systems need a dedicated circuit and a local isolator. All electrical work must comply with the Wiring Regulations.
- Condensate
- Water from the indoor unit must drain by gravity or through a condensate pump, piped to a suitable drain instead of left to drip.
- F-Gas
- Under UK F-Gas rules, anyone installing, servicing or repairing equipment containing fluorinated refrigerants must hold the appropriate certification. Ask to see it.
- Leak checks
- Systems above certain refrigerant charge thresholds need periodic leak checks and records, which matters on larger commercial sites.
- Planning
- Sherburn in Elmet is under North Yorkshire Council. Commercial premises don’t have the same permitted development rights as homes, so check outdoor unit positions with the council or your landlord.
Roof-mounted outdoor units
On business parks, outdoor units often go on the roof or high on an outside wall, out of the way of vehicles and yard work. That brings up safe access for fitting and future servicing, what load the roof can take and how the roof covering is protected. Access equipment and any roof work go on the quote, since they can affect the price. Sites with lots of rooftop kit are usually best on a planned air conditioning maintenance schedule.
Planned maintenance across a multi-unit site
Business systems run longer hours than a home system, often somewhere dustier, so they need a regular schedule. We set the visit frequency around how hard each unit works.
Asset list
We record each indoor and outdoor unit, where it is and what it serves, so nothing gets missed on later visits.
Agreed frequency
Offices may need one visit a year. Warehouse staff areas and canteens near dusty operations usually need more.
Each visit
Filters and coils cleaned, fans and drains checked, electrical connections inspected, operating pressures and temperatures checked, and controls tested.
Clear reporting
You get a note of what was done and anything that needs attention, so you can plan repairs or replacements.
For a single system, our air conditioning servicing page explains a standard annual service.
Reducing downtime when a unit stops working
When an office or welfare-room unit fails in a warm spell, what you need is a quick, accurate diagnosis. Giving us the right details when you ring helps a lot.
- Note any error code shown on the controller or indoor unit.
- Check whether the filters are clogged and whether the outdoor unit is running.
- Look for water dripping from the indoor unit or ice on the pipework.
- Switch the system off if it’s leaking water or making unusual noises.
- Call 0191 743 9144 and describe what you’ve found.
With air conditioning repairs, we explain the cause and the options before any work goes ahead.
Getting a Sherburn quote: what helps
A survey and a written quote come first, free and with no obligation. On business sites, a bit of information up front makes the visit more useful.
- Floor plans or rough room dimensions, if you have them
- How many people use each room and at what times
- Any landlord, managing agent or site rules on external equipment and roof access
- Where the electrical distribution board is, and who to speak to about it
- Preferred times for work, such as outside shift changes or at weekends